Air Conditioning

Airflow solutions for Air Conditioning manufacturers

Revcor engineers impellers and airflow assemblies for air conditioning OEMs. We help define airflow, pressure, sound, and packaging requirements, then configure or develop a solution and validate performance under representative operating conditions. We manufacture and support validated impellers and assemblies throughout production.

Market Focus

Commercial

Commercial cooling equipment serves offices, retail stores, restaurants, and hotels with different occupancy patterns, cooling loads, and installation requirements. OEMs developing rooftop units, split systems, air handlers, and fan coils must deliver the required cooling airflow across equipment families with multiple capacities, coil options, and filtration packages.

Development must account for how those configurations perform within the intended duct-pressure range, operating modes, and installation footprint. Revcor engineers impellers and airflow assemblies around these conditions, helping OEMs establish validated fan performance for the configurations their customers will specify.

Common OEM Challenges

How Revcor Helps

01
Challenge

Deliver cooling airflow across the intended duct-pressure range

The same commercial cooling unit may serve an open retail floor or a divided office layout with different duct resistance. The blower must deliver the airflow specified for the cooling coil across the equipment’s intended external static-pressure range. A selection based on one nominal point can leave insufficient airflow at higher resistance or require speed and power beyond the intended motor limits.

01
How Revcor Helps

Establish system performance across the specified pressure range

Revcor works with your team to define the cooling airflow target, internal equipment losses, and intended external static-pressure range. We configure or develop the impeller or assembly and evaluate airflow, power input, and motor requirements at the agreed points. Validation establishes the airflow package’s performance range for use in the OEM’s equipment development and application guidance.

02
Challenge

Account for changing airflow conditions across cooling and economizer modes

Rooftop units and air handlers may provide mechanical cooling, economizer operation, or a combination of the two. Changes in outdoor-air and return-air damper positions can alter resistance and the flow entering the blower. Variable-air-volume operation adds further operating points, so performance established in one configuration may not represent every mode the cooling unit must support.

02
How Revcor Helps

Validate the fan duties associated with each equipment mode

We define the airflow, pressure, and relevant inlet conditions for the operating modes specified by your team. Revcor evaluates impeller performance and motor requirements against those duties, with representative restrictions included in the validation plan. Where mixing sections or nearby transitions create an unresolved shortfall, evaluation of a complete, testable unit or representative assembly can help identify the limiting conditions.

03
Challenge

Control sound near customers, guests, and employees

Ceiling-mounted fan coils serving hotel rooms, air handlers near offices, and rooftop units connected to occupied spaces present different sound constraints. The fan must meet those constraints at the speeds needed to deliver cooling airflow through the selected coil and duct system. Recovering lost airflow by increasing speed late in development can leave the OEM with limited options for meeting both requirements.

03
How Revcor Helps

Resolve airflow and sound requirements together

Revcor establishes sound targets alongside cooling airflow and pressure requirements, then evaluates impeller geometry, operating speed, and representative inlet and discharge conditions together. Validation addresses the routine and higher-demand operating points defined for the product. The results help your team assess fan configurations before committing to cabinet geometry and motor requirements.

04
Challenge

Fit updated cooling performance into established rooftop footprints

Replacement rooftop units may need to accommodate existing roof curbs, duct openings, and installation dimensions. Changes to cooling coils or filtration can consume space previously available for the blower and its transitions. Meeting the external footprint does not establish that the internal airflow path can deliver the required cooling within power and sound limits.

04
How Revcor Helps

Engineer around cabinet and airflow-path constraints

We review the available fan envelope, mounting requirements, coil relationship, and inlet and discharge geometry with your team. Proven Revcor platforms are configured first, with new impeller geometry or assemblies developed when existing options cannot meet the combined dimensional and performance requirements. Validation accounts for representative cabinet restrictions and airflow transitions within the agreed scope.

05
Challenge

Maintain airflow performance across equipment configurations

A commercial cooling family may offer several capacities, coil arrangements, filtration packages, and cabinet sizes. Those changes affect both the required airflow and the resistance the fan encounters. Carrying one fan configuration across the family without evaluating each required duty can create gaps in airflow capability, power performance, or motor suitability.

05
How Revcor Helps

Match configurations to the product family’s requirements

Revcor works with your team to establish the airflow, pressure, packaging, and operating requirements for the specified equipment configurations. We assess where a proven impeller platform can support multiple duties and where another configuration or new development is needed. Agreed operating points are validated, with motor requirements established for each defined configuration before the impellers or assemblies move into production.